Best Price for 40.5kv Ac Vacuum Load Break Switch - FN7-12 Series Indoor High Voltage Air Load Break Switch – Ghorit Detail:
FN7-12 is a new type of air indoor high-voltage load break switch. It is suitable for AC 50Hz, rated voltage 12kV three-phase AC power system, as the breaking load current and closing short-circuit current.
Type Description

Working Conditions
● Ambient temperature: -25 °C~ 40°C;
● Altitude: <1000m;
● Relative humidity: daily average <95%; Monthly average <90%;
● There shall be no corrosive, combustion and explosion gas or vapor on the site;
● No frequent violent vibration.
Technical Parameters
Main specifications Note: (-) without (A) with Table 1
| Name |
Type |
Model |
DS |
DX |
L |
R |
RA |
F |
| Earth switch
at inlet |
Earth switch at outlet |
Interlock device |
Fuse |
Striker fuse |
Electric opening device |
|||
|
Load break switch |
Without tripper |
FN7-12 |
- |
- |
- |
- |
- |
- |
|
FN7-12DSL |
A |
- |
A |
- |
- |
- |
||
|
FN7-12DXL |
- |
A |
A |
- |
- |
- |
||
|
FN7-12R |
- |
- |
- |
A |
- |
- |
||
|
FN7-12DSLR |
A |
- |
A |
A |
- |
- |
||
|
FN7-12DXLR |
- |
A |
A |
A |
- |
- |
||
|
With striking tripper |
FN7-12RA |
- |
- |
- |
- |
A |
- |
|
|
FN7-12RAF |
- |
- |
- |
- |
A |
A |
||
|
FN7-12DXLRA |
- |
A |
A |
- |
A |
- |
||
| FN7-12DXLRAF |
- |
A |
A |
- |
A |
A |
Rated parameters Table 2
|
Rated voltage kV |
Max. voltage kV |
Rated current A |
1min power frequency withstand voltage kV |
4s thermal stability current(RMS) kA |
Dynamic stability current(peak) kA |
Short circuit making current kA |
Rated breaking current A |
Rated transferring current A |
|
12 |
12 |
400 |
42/48 |
12.5 |
31.5 |
31.5 |
400 |
1000 |
| 630 |
42/48 |
20 |
50 |
50 |
630 |
1000 |
Rated parameters of fUse Table 3
|
Model |
Rated voltage kV |
Rated current A |
Rated current of fuse |
| SDLA*J |
12 |
40 |
6,3,10,16,20,25,31.5,40 |
| SFLA*J |
12 |
100 |
50,63,71,80,100 |
| SKLA*J |
12 |
125 |
125 |
A*: with striker.
General Structure Drawing and Installation Size ( unit mm )
1. Arc Extinguishing Knife 2. Arc Contact Part and Arc Extinguishing Chamber 3. Insulator 4. Base
5. Dynamic Contact Knife 6. Static Contact Knife 7. Spring energy storage device (inside the main axis sleeve) 8. Main knife turning arm
Drawing 1 FN7-12 load switch outline and installation size

1.Arc Extinguishing Knife 2.Arc Contact Part and Arc Extinguishing Chamber 3. Insulator 4. Base
5. Dynamic Contact Knife 6. Static Contact Knife 7. Spring energy storage device (inside the main axis sleeve)
8. Earthing Knife 9. Main knife closing turning arm 10. Earthing knife closing turning arm
Drawing 2 FN7-12DXL load switch outline and installation size
1.Arc Extinguishing Knife 2.Arc Contact Part and Arc Extinguishing Chamber 3. Insulator 4. Earthing knife
5. Base 6. Dynamic Contact Knife 7* Static Contact Knife 8. Fuse 9* Spring energy storage device (inside the main axis sleeve)
10. Earthing energy-storage spring 11. Interlock device 12. Main knife closing&opeing turning arm
13. Earthing knife closing&opening turning arm
Drawing 3 FN7-12DXLR separated type load switch outline and installation size
1.Arc Extinguishing Knife 2.Arc Contact Part and Arc Extinguishing Chamber 3. Insulator 4. Base
5. Dynamic Contact Knife 6. Static Contact Knife 7. Spring energy storage device (inside the main axis sleeve)
8. Fuse 9. Main knife closing&opening turning arm
Drawing 4 FN7-12R separated type load switch outline and installation size
1 .Arc Extinguishing Knife 2.Arc Contact Part and Arc Extinguishing Chamber 3. Impact type Fuse 4. Insulator Base 5. Earthing knife
6. Base 7. Dynamic Contact Knife 8. Main knife closing spring 9. Static Contact Knife 10. Earthing energy-storage spring
11. Main knife opening spring 12. Interlock device 13. Main knife closing&opeing turning arm m 14.Earthing knife closing&opening turning arm
Drawing 5 FN7-12DXLRA integrated type load switch outline and installation size

1.Arc Extinguishing Knife 2. Arc Contact Part and Arc Extinguishing Chamber
3. Insulator 4. Base 5. Dynamic Contact Knife 6. Static Contact Knife
7. Spring energy storage device (inside the main axis sleeve) 8. Plate
Drawing 6 FN7-12C load switch outline and installation size

1.Arc Extinguishing Knife 2. Arc Contact Part and Arc Extinguishing Chamber
3. Insulator 4. Base 5. Dynamic Contact Knife 6. Static Contact Knife
7. Spring energy storage device (inside the main axis sleeve) 8. Fuse 9. Plate
Drawing 7 FN7-12CR separated type load switch outline and installation size

1.Arc Extinguishing Knife 2. Arc Contact Part and Arc Extinguishing Chamber 3. Impact type fuse 4. Earthling knife
5. Insulator 6. Base 7. Main knife closing spring 8. Dynamic Contact Knife 9. Static Contact Knife
10.Earthing energy storage spring 11. Main knife opening spring 12.Plate 13. Drawing 11
Drawing 8 FN7-12CDXLRA integrated type load switch outline and installation size
Product detail pictures:


Related Product Guide:
Sticking to the principle of "Super Quality, Satisfactory service" ,We are striving to be a good business partner of you for Best Price for 40.5kv Ac Vacuum Load Break Switch - FN7-12 Series Indoor High Voltage Air Load Break Switch – Ghorit, The product will supply to all over the world, such as: Guatemala, Barbados, Bulgaria, We are very responsible for all details on our customers order no matter on warranty quality, satisfied prices, quick delivery, on time communication, satisfied packing, easy payment terms, best shipment terms, after sales service etc. We provide one-stop service and best reliability to our every customers. We work hard with our customers, colleagues, workers to make a better future.
By Katherine from India - 2018.09.19 18:37
In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
By Georgia from Brisbane - 2018.05.15 10:52
-
Massive Selection for Instruments Transformer -...
-
Wholesale Dry Cast Resin Transformer - GHV-12G...
-
100% Original Current Transformer 5a - JDZXW-3...
-
China wholesale Pole Mounted Automatic Outdoor ...
-
2020 Good Quality Vacuum Bottle Interrupter - ...
-
OEM Supply Current Transformer - JDZX11-35R ty...