◆ Use Conditions
Altitude: ≤2000m;
Ambient air temperature: -45℃~+50℃;
Relative humidity: daily average ≤95%, monthly average ≤90%;
It is not suitable for installations where there is frequent and severe vibration, water vapor, gas, chemical corrosive deposits, salt spray, dust and dirt, and fire and explosion hazard installations that obviously affect the performance of the mechanism.
The rated SF6 gas pressure is 0.04MPa, and the SF6 gas meets the requirements of GB/T 12022-2014 “Industrial SF6″.
◆Main Technical Parameters
|
NO. |
Items |
Unit |
Value |
|
1 |
Rated voltage |
kV |
12 |
|
2 |
Rated frequency |
Hz |
50 |
|
3 |
Rated current |
A |
630 |
|
4 |
Rated short time withstand current |
kA |
20, 25 |
|
5 |
Rated peak withstand current |
kA |
50 |
|
6 |
Rated short circuit duration |
S |
4 |
|
7 |
Rated short circuit making current |
kA |
50 |
|
8 |
Theoretical operation |
Times |
10000 |
|
9 |
Main circuit resistance |
μΩ |
≤60 |
|
10 |
1min power frequency withstand voltage |
kV |
38 (in air) |
◆ Overall Dimensions
Product detail pictures:

Related Product Guide:
"Sincerity, Innovation, Rigorousness, and Efficiency" is definitely the persistent conception of our corporation to the long-term to establish alongside one another with customers for mutual reciprocity and mutual profit for Hot sale Factory China Manufacturer Outdoor 36kv Auto Recloser Best Price - GHV-12G/630 Circuit Breaker for C-GIS (with Disconnecting, without Earthing) – Ghorit, The product will supply to all over the world, such as: Armenia, Austria, Mumbai, we sincerely hope to establish a good and long-term business relationship with your esteemed company through this opportunity, based on equality, mutual benefit and win-win business from now to the future. "Your satisfaction is our happiness".
By Natividad from Lebanon - 2018.11.22 12:28
The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
By Sandy from Stuttgart - 2018.02.12 14:52
-
PriceList for Air Load Break Switch - GN30-12(...
-
Short Lead Time for High Precision Current Tran...
-
Wholesale Dry Cast Resin Transformer - LXK-<...
-
Cheapest Price High Voltage Disconnect Switch -...
-
2020 New Style 630 Amp Vacuum Circuit Breaker -...
-
Hot New Products Vacuum Interrupters - Vacuum ...