Manufactur standard Load Break Switch Lbs - FN12-12 Series Indoor High Voltage Air Load Break Switch – Ghorit Detail:
FN12-12 indoor HV air load break switch is a 3-phase AC 50Hz 12kV indoor switch equipment.
♦ Installation way: front-mounted, side mounted, flip mounted;
♦ Operating mechanism: spring operating mechanism, manual type and electrical type available;
♦ Operation type: right operation and left operation;
♦ Application: indoor 12kv switchgear.
Environmental Conditions
♦ Ambient temperature: -25°C 〜+40°C;
♦ Altitude: <1000m (above sea level);
♦ Relative humidity: daily average <95%, monthly average <90%;
♦ Earthquake intensity: <8 level;
♦ Pollution grade: II;
♦ Places without fire, explosion, chemical corrosion and serious vibration.
Main Technical Parameters
|
NO |
Item | Unit |
FN12-12D/6 30-20 |
FN12-12RD/1 25-31.5 |
||
|
1 |
Rated voltage |
kV |
12 |
12 |
||
|
2 |
Rated frequency |
Hz |
50 |
50 |
||
|
3 |
Rated current | A |
630 |
125 |
||
|
4 |
1min power frequency withstand voltage (Phase to earth, between poles, open contacts) | Phase-to-earth, phase-to-phase |
kV |
42 |
42 |
|
| Isolating fracture |
48 |
48 |
||||
|
5 |
Rated lightning impulse withstand voltage (Phase to earth, between poles, open contacts) | Phase-to-earth, phase-to-phase |
kV |
75 |
75 |
|
| Isolating fracture |
85 |
85 |
||||
|
6 |
Rated short time withstand current (thermal stability current) | Load break switch |
kA |
20 |
||
| Earth switch |
20 |
|||||
|
7 |
Rated short circuit duration ( thermal stability time) | Load break switch | s |
4 |
||
| Earth switch |
2 |
|||||
|
8 |
Rated short circuit making current (peak) |
kA |
50 |
|||
|
9 |
Rated breaking current | Active load breaking current | A |
630 |
||
| Loop breaking current |
630 |
|||||
| 5% active load breaking current |
31.5 |
|||||
| Cable charging current |
10 |
|||||
| No-load transformer capacity | kVA |
1250 |
||||
| 10 | Rated short circuit breaking current (limit current fuse) |
kA |
31.5 |
|||
| 11 | Rated transfer current | A |
1200 |
|||
| 12 | Mechanical life |
times |
2000 |
2000 |
||
| 13 | Striker output energy | J | 1±0.5 | |||
General Structure Drawing and Installation Size (unit: mm)
♦ FN12-12D (side-mounted left operation)
♦ FN12-12D (flip-mounted left operation)
♦ FN12-12RD (front side-mounted left operation)
♦ FN12-12RD (front flip-mounted left operation)
Product detail pictures:

Related Product Guide:
Each individual member from our large performance revenue crew values customers' needs and company communication for Manufactur standard Load Break Switch Lbs - FN12-12 Series Indoor High Voltage Air Load Break Switch – Ghorit, The product will supply to all over the world, such as: South Africa, Argentina, Mauritius, We mainly sell in wholesale, with the most popular and easy ways of making payment, which are paying via Money Gram, Western Union, Bank Transfer and Paypal. For any further talk, just feel free to contact our salesmen, who are really good and knowledgeable about our prodcuts.
By Arthur from South Africa - 2018.12.22 12:52
This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
By Louise from Zambia - 2017.06.25 12:48
-
Factory Outlets Fuse Switch Disconnector - FZR...
-
Manufacturing Companies for Combination Switch ...
-
Rapid Delivery for Outdoor Isolator - GHV-12G/...
-
Factory Cheap 27kv Outdoor Recloser - GHV-12G/...
-
Hot Sale for Indoor Disconnect Switch - Jn15-2...
-
Chinese Professional 1600 Amp Circuit Breaker -...