We have now probably the most innovative production equipment, experienced and qualified engineers and workers, regarded high quality control systems and also a friendly expert income team pre/after-sales support for 33kv Current Transformer, 12kv Outdoor Vacuumm Interrupter, Switch Disconnector, Safety as a result of innovation is our promise to each other.
Manufacturer for Medium Voltage Vacuum Interrupters - Vacuum Interrupter For Indoor Circuit Breakers TD-40.5/1250~1600-31.5 (4D58) – Ghorit Detail:

wer

Notes

1. Meets or exceeds the electrical endurance requirements of  class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003.

2. Rated characteristics tobe givenon request.

3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc.

Main Technical Specifiation

Rated Voltage

KV

40.5

Rated Current

A

1250/1600
Rated Frequency

Hz

50

Short-time power-frequency Withstand Voltage(1min)

KV

95

Rated lightning Impulse Withstand Voltage(Peak)

KV

185

Rated Short-circuit Brenking Current

KA

31.5

Rated Peak Withstand Current

KA

80

Rated Short-circuit Making Current

KA

80

Rated Short-time Withstand Current

KA

31.5

Rated Duration of Short-circ

S

4

Rated Single Capacitor Bank Breaking Current

A

400

Rated Back to Back Capacitor Bank Breaking Current

A

400

Rated Short-circuit Making Current

Times

20

Mass of Moving Parts

Kg

2.7

Mechanical Endurance

Times

10000

Contact Closed Force Due to Bellows and Atmosphere

N

210±50
Counterforce of Contact at Full Stroke

N

320±30
Circuit Resistance at Min.Rated Contact Force  μΩ

<20

Contact Limit Erosion

mm

3

Storage Life

Years

20

Mechanical Data Of Vacuum Switch Equipped With The Interrupters

Clearance Between Open Contacts

mm

22±2

Average Opening Speed

m/s

1.6±0.2

Average Closing Speed

m/s

1.3±0.2

Rated Contact Pressure

N

3200±200

Contact Bounce Duration at Closing Operation

ms

<3

Out of Simultaneity of Contact Closing and Operation

ms

<2

Maximum Rebound During Opening

mm

<2


Product detail pictures:

Manufacturer for Medium Voltage Vacuum Interrupters - Vacuum Interrupter For Indoor Circuit Breakers TD-40.5/1250~1600-31.5 (4D58) – Ghorit detail pictures


Related Product Guide:

To become the stage of realizing dreams of our employees! To build a happier, much more united and far more professional team! To reach a mutual profit of our clients, suppliers, the society and ourselves for Manufacturer for Medium Voltage Vacuum Interrupters - Vacuum Interrupter For Indoor Circuit Breakers TD-40.5/1250~1600-31.5 (4D58) – Ghorit, The product will supply to all over the world, such as: Casablanca, Belgium, Swaziland, We pay high attention to customer service, and cherish every customer. We have maintained a strong reputation in the industry for many years. We are honest and work on building a long-term relationship with our customers.
  • Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 StarsBy Anne from kazan - 2018.12.25 12:43
    We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
    5 StarsBy Judy from Turin - 2018.06.18 17:25