Vacuum Interrupter (VI)

  • Embedded Pole For Indoor Circuit Breakers EP-12/630-25 EP-12/1250-25 EP-12/1250-31.5

    Embedded Pole For Indoor Circuit Breakers EP-12/630-25 EP-12/1250-25 EP-12/1250-31.5

    Notes 1. Meets or exceeds the electrical endurance requirements of class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 12 Rated Current A 630/1250 Rated Frequency Hz 50 Short-time power-frequency Withstand Voltage(1min) KV 48 Rated lightning Impulse Withstan...
  • Vacuum interrupter for load break switch TF-12/630-20 (2F56)

    Vacuum interrupter for load break switch TF-12/630-20 (2F56)

    Notes 1. Meets or exceeds the electrical endurance requirements of class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 12 Rated Current A 630 Rated Frequency Hz 50 Short-time Power-frequency Withstand Voltage(1min) KV 42 Rated lightning Impulse Withstand Vo...
  • Vacuum Interrupter For Load Break Switch TF-12/630-20 (2F55)

    Vacuum Interrupter For Load Break Switch TF-12/630-20 (2F55)

    Notes 1. Meets or exceeds the electrical endurance requirements of class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 12 Rated Current A 630 Rated Frequency Hz 50 Short-time Power-frequency Withstand Voltage(1min) KV 42 Rated lightning Impulse Withstand Vo...
  • Vacuum Interrupter For Outdoor Circuit Breakers TD-40.5/1250-31.5 (4D86)

    Vacuum Interrupter For Outdoor Circuit Breakers TD-40.5/1250-31.5 (4D86)

    Notes 1. Meets or exceeds the electrical endurance requirements of class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 40.5 Rated Current A 1250 Rated Frequency Hz 50 Short-time power-frequency Withstand Voltage(1min) KV 95 Rated lightning Impulse Withstand...
  • Vacuum Interrupter For Outdoor Circuit Breakers TD-40.5/1250-31.5 TD-40.5/1600-31.5

    Vacuum Interrupter For Outdoor Circuit Breakers TD-40.5/1250-31.5 TD-40.5/1600-31.5

    Notes 1. Meets or exceeds the electrical endurance requirements of class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 40.5 Rated Current A 1250/1600 Rated Frequency Hz 50 Short-time power-frequency Withstand Voltage(1min) KV 95 Rated lightning Impulse Withst...
  • Vacuum Interrupter For Outdoor Circuit Breakers TD-24/630-20 (3D82)

    Vacuum Interrupter For Outdoor Circuit Breakers TD-24/630-20 (3D82)

    Notes 1. Meets or exceeds the electrical endurance requirements of  class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 24 Rated Current A 630 Rated Frequency Hz 50 Short-time power-frequency Withstand Voltage(1min) KV 65/79 Rated lightning Impulse Withstan...
  • Vacuum Interrupter For Outdoor Circuit Breakers TD-12/1250-25 (2D89B)

    Vacuum Interrupter For Outdoor Circuit Breakers TD-12/1250-25 (2D89B)

    Notes 1. Meets or exceeds the electrical endurance requirements of  class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 12 Rated Current A 1250 Rated Frequency Hz 50 Short-time power-frequency Withstand Voltage(1min) KV 48 Rated lightning Impulse Withstand ...
  • Vacuum Interrupter For Outdoor Circuit Breakers TD-12/630-25 (2D89)

    Vacuum Interrupter For Outdoor Circuit Breakers TD-12/630-25 (2D89)

    Notes 1. Meets or exceeds the electrical endurance requirements of  class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3 .Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 12 Rated Current A 630 Rated Frequency Hz 50 Short-time power-frequency Withstand Voltage(1min) KV 48 Rated lightning Impulse Withstand V...
  • Vacuum Interrupter For Outdoor Circuit Breakers TD-12/630-25 (2D88)

    Vacuum Interrupter For Outdoor Circuit Breakers TD-12/630-25 (2D88)

    Notes 1. Meets or exceeds the electrical endurance requirements of class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 12 Rated Current A 630 Rated Frequency Hz 50 Short-time power-frequency Withstand Voltage(1min) KV 48 Rated lightning Impulse Withstand Vo...
  • Vacuum Interrupter For Outdoor Circuit Breakers TD-12/1250-25 (2D85E)

    Vacuum Interrupter For Outdoor Circuit Breakers TD-12/1250-25 (2D85E)

    Notes 1. Meets or exceeds the electrical endurance requirements of  class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 12 Rated Current A 1250 Rated Frequency Hz 50 Short-time power-frequency Withstand Voltage(1min) KV 42/48 Rated lightning Impulse Withstand...
  • Vacuum Interrupter For Outdoor Circuit Breakers TD-12/1250-25 (2D85E)

    Vacuum Interrupter For Outdoor Circuit Breakers TD-12/1250-25 (2D85E)

    Notes 1. Meets or exceeds the electrical endurance requirements of class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation Rated Voltage KV 12 Rated Current A 1250 Rated Frequency Hz 50 Short-time power-frequency Withstand Voltage(1min) KV 48 Rated lightning Impulse Withstand V...
  • Vacuum Interrupter For Outdoor Circuit Breakers TD-12/630-25 (2D85)

    Vacuum Interrupter For Outdoor Circuit Breakers TD-12/630-25 (2D85)

    Notes 1. Meets or exceeds the electrical endurance requirements of  class E2 for autoreclosing duty per IEC62271-100 and GB1984-2003. 2. Rated characteristics tobe givenon request. 3. Rated insulation valuesrequire extemal insulati on, such as Sf6, oil or solid dielectric material etc. Main Technical Specifiation  Rated Voltage KV 12 Rated Current A 630 Rated Frequency Hz 50 Short-time power-frequency Withstand Voltage(1min) KV 42/48 Rated lightning Impulse Withstand...